Dyna GCOL-A

● Specification

Test Item

Specification

Apperance in water

Light Amber Fluid

...Specific Gravity(15/4℃)

1.10

.....Viscosity, cSt, 40℃

2,600

...Flash Point(COC), ℃

None

.Cloud Point ℃

74℃

...Pour Point ℃

-12.5℃

...pH(20℃, 5%Sol'n)

9.40


● Features
- If adsorbed films are formed by temperature difference of aqueous solution, PAG films are formed on treated surfaces when red heat metal is soaked in GCOL-A solution and forming of vapor blanket is restrained. As a result, cracking does not occur and deformation is reduced because uniform heat is extracted and uniform hardening is performed even on complex structures.
- Low risk of fire because both diluted and undiluted chemicals are non-flammable so it is environmentally safe.
- It does not deteriorate because it is semi-permanent use possible by refilling.
- Enables the attainment of an ideal cooling curve, through the control of concentration, fluid temperature and flow speed.
- Concentration can be measured by saccharometer and is easily controlled.
- Prevents problems usually associated with uniform quenching because of its excellent antifoaming power.
- Enables tempering without prior degreasing.

● Technology and Certification
- Patent No. 0248825

● Additional Information

▶ Application
- continuity furnace (belt, pusher, rotary type)
- A wide range of cooling effect used for mid carbon steel, low alloyed steel
- Flux process of light metals like alloyed aluminum and alloyed Ti

▶ Packing
- Drum--------------------------------200 L/T
- Pail---------------------------------20 L/T