Residual chlorine Measuring Device
The system to supply safe water by confirming the residual chlorine density that is input by the automatic chlorine input device of a small-scaled water supply facilities Patent registration 0318795 The product that has been selected as a good project by SMBA
Characteristic
- Continuous density indication type of non-agents
- Replacement of only a tip-type electrode when it is damaged (cost-saving)
- The system only for portable water of waterwoks, small-scaled waterworks and etc. (automatic control by interworking with peripherals)
- High/low alarm function by setting a residual chlorine density
- PC-compatible by adopting RS-232(information record and output)
- Various power application (AC/DC/solar energy)
- Price competitiveness against 1/3 of exported products
Component of product
- Detector
This is the water quality analysis device at a site and is designed to measure the residual chlorine density in real-time in the water quality management and water treatment process. And it is equipped with the self-diagnosis, manual/automatic adjustment, front lamp LCD Tor operation and data storage function by a microprocessor.
- Sensor
The residual chlorine sensor (Gilvanic method) is an electrode sensor of continuous measurement with the non-agents type, and its electrode material consists of Pt, Ag and AgCl.
- Flow holder and filter housing
The holder is the supplementary device that makes the residual chlorine sensor to maintain good sensitivity for a long time, and it prevents foreign substance from being adsorbed to the sensor by controlling a sample with a constant flow speed to be touched.
- Module of electricity supply by solar energy
The solar cell module has solar cells that are connected in series, and produces and supplies DC current, which is required for the device's operation
* Water quality analysis meter
* Turbidity meter
* Electrical conductivity meter
* Dissolved oxygen meter
* pH meter